Scriptware Commands¶
UMR provides a variety of “scriptware” commands that make writing shell scripts
around UMR easier. They are all invoked with the --script command and take a
variable number of arguments per command.
If you invoke umr without any --script options it will list the currently supported
scriptware commands:
$ umr --script
Available umr --script commands:
instances
List all AMDGPU instances in space delimited format
pci-instances <did>
List all AMDGPU instances matching a given PCI DID in space delimited format
pci-did <instance>
Output the PCI device ID (did) of the AMDGPU device with a given instance
pci-bus <instance>
Output the PCI device bus address of the AMDGPU device with a given instance
pci-bus-to-instance <busno>
Output the DRI instance matching a PCI device bus address
pci-bus-to-instxcc <busno>
Translate a PCI bus address with XCC encoded PCI function into a pair of -i and -vmp
xcds <instance>
List all GC partitions for a given device
gfxname <instance>
Outputs the base name for the GC IP block of a given GPU instance
instances¶
The instances command lists all of the available AMDGPU DRI instances in the
system in space delimited format.
$ umr --script instances
1 2
In this example instance 1 and 2 are valid AMDGPU devices. This can be used in for instance a bash for loop to iterate over all of the AMDGPU devices.
$ for i in `umr --script instances`; do umr -i ${i} -r *.*.RB_BASE; done
Would read any registers matching the partial text RB_BASE from every AMDGPU device in the system.
pci-instances¶
This command lists all of the AMDGPU instances that match a given PCI device ID (did) in space delimited format.
$ umr --script pci-instances 0x7448
1
Indicates that only device instance 1 has the PCI device ID of 0x7448.
pci-did¶
This command outputs the PCI device ID of a given DRI instance device.
$ umr --script pci-did 1
0x7448
Indicates that device instance 1 has the PCI device ID of 0x7448.
pci-bus¶
This command outputs the PCI bus address given a DRI instance as input.
$ umr --script pci-bus 1
0000:03:00.0
This indicates that the PCI bus address of instance 1 is 0000:03:00.0.
pci-bus-to-instance¶
This command translates a PCI bus address back to a DRI instance number. Useful when logs emit the PCI bus address but not the DRI instance.
$ umr --script pci-bus-to-instance 0000:03:00.0
1
This indicates that the AMDGPU device with PCI bus address 0000:03:00.0 has a DRI instance of 1.
pci-bus-to-instxcc¶
This command translates a PCI bus address that also includes the XCC id encoded as a the PCI bus function back to a DRI instance number. Useful when logs emit the PCI bus address but not the DRI instance.
$ umr --script pci-bus-to-instxcc 0000:03:00.2
-i 1 -vmp 2
Because this command outputs two values, it also includes the umr command line syntax to specify them. This allows you to use the output directly as further umr parameters.
xcds¶
This command lists all of the XCDs of a given ASIC (the parameter you pass into -vmp when selecting
a GC or MMHUB instance) in space delimited format. If the device has no partitioning it will emit -1 to
be compatible with the -vmp input required on those hosts.
$ umr --script xcds 1
-1
In this case this device has only one GC and no partitioning so it emits -1.
gfxname¶
This command emits the IP name of the GC (gfx) block for a given DRI instance.
$ umr --script gfxname 1
gfx1100
Which is useful if you want to read only from GC blocks in a script. On partitioned hosts this will not emit any curly brace syntax.